Bug 1326 : "An error occurred while starting the application" with sketchbook on a network disk and on non US-English systems running Windows
Last modified: 2009-10-25 11:12




Status:
RESOLVED
Resolution:
WONTFIX -
Priority:
P2
Severity:
normal

 

Reporter:
ubBoO.momentum
Assigned To:
fry

Attachment Type Created Size Actions

Description:   Opened: 2009-09-14 13:10
I configure my processing (1.0.7) sketchbook folder on a network disk
instead of the default "my documents" folder.

When I launch processing from a Vista or XP computer in French, I get this
error "Launch4j | An error occurred while starting the application", the
startup take a long time (2 minutes), but finally the application is
running fine.

If I launch processing on a XP in english, using the same network disk, I
got no error and the startup take only 15 seconds.
Additional Comment #1 From ubBoO.momentum 2009-09-30 13:24
Is it possible to produce some log file to help you what is happening?

If yes, how to produce this one?

br

uBbOo
Additional Comment #2 From fry 2009-10-02 12:00
unfortunately there's not much to be done unless i have access to a system
with this setup and can debug it in depth.

i'd suggest mapping the network drive to a drive letter (if you aren't
already) since that often helps things, but outside that, there are just
too many possibilities that i can't really test it, sorry...
Additional Comment #3 From ubBoO.momentum 2009-10-25 11:12
I confirm that this issue seems solved with the version 1.0.9.